C-more micro EA1-S6MLW Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro ne C-more micro EA1-S6MLW. C-more micro EA1-S6MLW User manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 2
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
®
3505 HUTCHINSON ROAD
CUMMING, GA 30040-5860
Minimum items required to create a working system:
C-more 6” Micro-Graphic panel
C-more Micro-Graphic Programming Software EA-MG-PGMSW (Downloadable version available from the
AutomationDirect web site at no charge.)
C-more Micro-Graphic USB to RS232 Programming Cable Assembly EA-MG-PGM-CBL, used to connect
between a PC and the Micro-Graphic panel’s built-in serial port. The panel will operate in Low-Power mode
when powered by the PC and the screen brightness is diminished.
• Power source – An external 12-24 VDC power source is required for normal High-Power operation.
Recommended power supplies are AutomationDirect part numbers PSC-24-015 or PSC-24-030.
• Personal computer – to run the C-more Micro-Graphic programming software
• Communications Cable (serial) – to connect the C-more Micro-Graphic panel to your controller
B
efore you begin...
Become Familiar with Available Communication Ports
Accessing the C-more Micro-Graphic Panel Setup Screens
Quick Start GuideQuick Start Guide
Quick Start GuideQuick Start GuideQuick Start Guide
Programming Software & Programming Cable (sold separately)
Copyright 2013, Automationdirect.com Incorporated/All Rights Reserved Worldwide
Agency Approvals
U
L
C
US
R
EA-MG-PGMSW
EA-MG-PGM-CBL
Additional Help and Support
Setup Menu
1. Information
1. Memory
2. Setting
1. LCD Contrast
2. Backlight
3. Beep
4. Calibration
5. Clear User Memory
1
. Serial Port1 – Loop Back Test
2
.
S
erial Port2 – Loop Back Tes
t
3. PLC Enquiry Test
D
o you want to exit from System Screen?
N
o[F1] / Yes[F5]
3. Test Menu
4. Exit
2
. Protocol
3. Extensions
4. Versions
6. Reset to Factory Default
7
. Hourglass
8. Rotation
4. Buzzer Test
5. Touch Panel Test
General Description
The C-more 6” Micro-Graphic panel has a 5.7-inch STN LCD monochrome 320 x 240 dot display. Model
EA1-S6ML has five selectable LED-driven backlight colors including Green, Red, Amber, Yellow and Lime.
Model EA1-S6MLW has five selectable LED-driven backlight colors including White, Pink1, Pink2, Pink3
and Red. Both models feature five user-defined function keys, each key with a user-defined red LED indi-
cator. The panels can display up to 40 lines by 80 characters of static text and up to 40 lines by 40 charac-
ters of dynamic text with embedded variables and phrases mixed with graphics at landscape orientation.
Portrait orientation can display 60 characters and 53 lines of static text and 40 lines by 40 characters of
dynamic text. Each model is rated UL for use on a flat surface of Type 1, 4X enclosure (indoor use only). The
C-more 6” Micro-Graphic panels are powered from a 12-24 VDC power supply or can operate in low-power
mode when powered from the serial communications port of select AutomationDirect PLCs.
Other features include:
• 1792 KB memory
• Built in RJ12 serial communications port (RS-232)
• Built in 15-pin serial communications port (RS-232/422/485)
• Adjustable contrast
• 2 optional keypad bezels, 20-button landscape and 21-button portrait mount
• Optional replaceable clear screen overlay
• Built in Alarm Control setup that activates beep, backlight flash, customized alarm banner, and red LED blinking
• Up to 999 screens, limited only by memory usage
• 0 to 50 °C (32 to 122 °F) operating temperature range
• UL, cUL & CE agency approvals (see below for details)
• 2-year warranty from date of purchase
Programming Software
USB to RS232 Programming
Cable Assembly
NOTE: Free download of the
CC--mmoorree
Micro-Graphic
programming software at the
AutomationDirect web site.
Safety Information
WARNING: To minimize the risk of potential safety problems, you should follow all applicable
local and national codes that regulate the installation and operation of your equipment. These
codes vary from area to area and it is your responsibility to determine which codes should be
followed, and to verify that the equipment, installation, and operation are in compliance with the
latest revision of these codes.
Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes
and standards. We do not guarantee the products described in this publication are suitable for your
particular application, nor do we assume any responsibility for your product design, installation, or
operation.
If you have any questions concerning the installation or operation of this equipment, or if you need
additional information, please call us at 1-800-633-0405 or 770-844-4200.
This publication is based on information available at the time it was printed. At
Automationdirect.com® we constantly strive to improve our products and services, so we reserve
the right to make changes to the products and/or publications at any time without notice and
without obligation. This publication may also discuss features that may not be available in certain
revisions of the product.
Connect C-more 6” Micro-Graphic Panel to PLC
Install the Software and Develop a Project
• For product support, specifications, and installation troubleshooting, a Hardware User Manual can be downloaded from
the On-line Documentation area of the AutomationDirect web site or purchased through the AutomationDirect Sales
team @ 1-800-633-0405 as part number EA1-MG6-USER-M.
• For software programming help, refer to the C-more Micro-Graphic Programming Software on-line embedded help.
• Refer to demos of the product at: www.CmoreMicro.com/software/software_demo.html
• For additional technical support and questions, call our Technical Support team @ 1-800-633-0405 or 770-844-4200.
Install C-more 6” Micro-Graphic Panel
NOTE: Recommended DC power supply to power the C-more Micro-Graphic Panel, AutomationDirect
Part No. PSC-24-015 or PSC-24-030.
T
o access the Setup Menu of the panel’s setup
screens, press the the BAK [F1] and ENT [F5]
function keys simultaneously for three (3) seconds.
From the Setup Menu, information about the panel
can be obtained, settings can be adjusted, and panel
functions can be tested.
M
enu flow Chart
Connect C-more Micro-Graphic Panel to Computer
Use an EA-MG-PGM-CBL, USB to RS-232 Programming Cable Assembly, from a USB port type A on the
project development PC, through the supplied converter, to the RJ12 RS-232 programming/PLC serial
communications port on the C-more Micro-Graphic panel as shown below.
C-more 6 inch
Micro Graphic
Panel
USB
Cable
User PC
S
erial
Cable
PC to Panel Programming
C
able Assembly
(Includes serial & USB cables)
EA-MG-PGM-CBL
USB to RS232
Converter
USB to RS-232
Programming Cable Assembly
C-more 6” Micro-Graphic Panels, Accessories & Replacement Parts
*NOTE:
CC--mmoorree
Micro-Graphic panels with the letter “W” in the part number designate units with
5 selectable background colors of White, Pink1, Pink2, Pink3 and Red. Part numbers without the
letter “W” are provided with 5 selectable background colors of Green, Red, Amber, Yellow and Lime.
NOTE: Software and Firmware Version 2.0 or later is required with models EA1-S6ML and
EA1-S6MLW. Available for free download at www.automationdirect.com.
EA1-S6MLW
shown in Portrait (Vertical) mode
EA1-S6ML
shown in Landscape (Horizontal) mode
Cutout
T
emplate
Function Key
Label Inserts
Mounting
Clips
C-more 6 Inch
Micro-Graphic
Panel
DC Power
C
onnector
1
Unpack and Inspect
• Unpack the C-more Micro-Graphic panel from its shipping
carton. Included in the carton are the following:
C-more 6” Micro-Graphic panel
• cutout template
• mounting clips
• gasket
• function key label inserts
• Quick Start Guide
• DC Power Connector
• Unpack any accessories that have been ordered, such as:
Keypad Bezel, DC Power Supply, programming cable,
communications cable, etc.
• Inspect all equipment for completeness. If anything is missing
or damaged, immediately call the AutomationDirect returns
department @ 1-800-633-0405.
2
Install Optional Hardware Accessories (sold separately)
C-more 6 Inch
Micro-Graphic Panel
20 Button
Keypad Bezel
EA-MG6-BZ2
1. Remove
Expansion
Connector
Protective
Cover from
rear of
panel.
2. Use the (4) Panel Mounting
Clips that are supplied with
the panel, to secure panel to
keypad bezel and compress
the gasket between the
panel and the keypad bezel.
Tighten screws to a torque
of 21-28 oz-in [0.15-0.2 Nm].
3. Use (8) Bezel Mounting Clips to
secure keypad bezel through
enclosure cutout. Tighten screws
to a torque of 21-28 oz-in
[0.15-0.2 Nm].
Function
Key Label
Insert
4. Peel Protective Film
from front of panel.
Shown is an example of a
C-more 6” Micro-Graphic
panel being assembled with
an optional 20-button
Keypad Bezel.
NOTE: Mounting clips for the
panel or keypad bezel are
included with each product
3
R
R
LISTED LISTED
7M17 7M17
Date code:**** Date code:****
5 5
4
4
3
3
2
2
1 1
R01. R01.
MADE IN CHINA MADE IN CHINA
EA1-S6MLW + serial number EA1-S6MLW + serial number
MODEL:EA1-S6MLW MODEL:EA1-S6MLW
INPUT:12-24V 6.5W INPUT:12-24V 6.5W
IND.CONT.EQ. IND.CONT.EQ.
Pin Signal
1 Logic GND
not used
RXD (232C)
TXD (232C)
2
3
4
5 +5 VDC
6 Logic GND
8 1
15
9
Pin Signal
1 Frame GND
TXD (232C)
RXD (232C)
do not use
2
3
4
5 Logic GND
Pin Signal Pin Signal
6 LE
CTS (232C)
RTS (232C)
RXD+ (422/485)
7
8
9
10 RXD– (422/485)
11 TXD+ (422/485)
TXD– (422/485)
Term. Resistor
do not use
12
13
14
15 do not use
RS-232
RS-232/422/485
Expansion
Connector
RJ12 serial
communications Port1
PLC 15-pin serial
communications Port2
The C-more 6” Micro-Graphic panels include a built-in RJ12 serial communications port (RS-232) used to
communicate with a PC during project development and later as a PLC communications interface. There is
also a second 15-pin RS-232/RS-422/RS-485 port for communications to a PLC.
Panel Cutout (all models)
Landscape cutout shown
The C-more 6” Micro-Graphic panel can be
mounted through a cutout in an enclosure by using
the template provided with the panel, or using the
dimensions shown. The optional keypad bezels also
include templates. The enclosure mounting thickness
range for the panels and the keypad bezels is
0.04”–0.2” [1–5 mm]. Mounting screw torque is 21-
28 oz-in [0.15-0.2 Nm].
ENCLOSURE MOUNTING
THICKNESS RANGE
0.04” - 0.2” [1 - 5mm]
Enclosure Thickness
0.260
[
6.6]
0
.256
[
6.5]
0
.256
[
6.5]
0
.260
[
6.6]
R .118 [R3]
CUTOUT
C
UTOUT
O
UTLINE
B
EZEL
O
UTLINE
122.2
+
1
–0
+
0.04
0.00
4
.811
1
61.0
+
1
–0
+
0.04
0.00
6.339
4
5
6
7
Provide Power to the C-more 6” Micro-Graphic Panel
1). The panel should be powered by a 1 Amp @ 12-24 VDC
class 2 power source in normal operation.
2). The C-more 6” Micro-Graphic panel is powered during
programming from the PC through the USB to RS-232
Programming Cable Assembly, EA-MG-PGM-CBL. When
powered from the PC, the panel will operate in Low-Power
mode.
3). Optionally, the C-more 6” Micro-Graphic panel can be
powered in Low-Power mode* from most AutomationDirect
PLC’s RJ12 serial communications port by using a
DV-1000CBL communications cable, or a DV-1000CBL
communications cable with a FA-15HD 15-pin HD
DSub/RJ12 Adapter connected to an AutomationDirect
PLC’s 15-pin HD communications port (DL06, D2-250-1 &
D2-260) PLCs. See Chapter 6: PLC Communications in the
Hardware User Manual (EA6-USER-M) for additional
details.
R
R
LISTEDLISTED
7
M177M17
Date code:****Date code:****
5
5443322
1
1
R
01.R01.
M
ADE IN CHINAMADE IN CHINA
EA1-S6MLW + serial numberEA1-S6MLW + serial number
MODEL:EA1-S6MLWMODEL:EA1-S6MLW
I
NPUT:12-24V 6.5WINPUT:12-24V 6.5W
IND.CONT.EQ.IND.CONT.EQ.
8
1
1
5
9
Supply to Panel:
1 A @ 12 - 24 VDC
(10.8 - 26.4 VDC)
+
GND
Equipment
Ground
Recommended
DC Supply Fuse
750 mA fast acting,
ADC p/n AGC-75
*NOTE: When the panel is powered through Port1 from a connected PLC or PC, the screen brightness
is diminished because the panel is running in Low-Power Mode. For full brightness, connect an
external 12-24 VDC power source to the panel’s power connection. Low-Power Mode should be
used during initial programming only. Connect an external 12-24 VDC power source when the
panel is installed in its application.
NOTE: Install C-more Micro-Graphic
Programming software before connecting
the panel to the PC to ensure the panel
drivers install correctly.
Following are the minimum system requirements for running C-more Micro-Graphic Programming
Software, EA-MG-PGMSW, on a PC:
• Operating System - Windows® XP Home / Professional Edition Service Pack 2, Window 2000 with Service Pack 4,
Window Vista (32 or 64 bit), Window 7 (32 or 64 bit) or Windows 8 (32 or 64 bit)
• Keyboard and Mouse or compatible pointing device
• Super VGA color video adapter and monitor with at least 800 x 600 pixels resolution
(1024 x 768 pixels recommended) 64K color minimum
• 150 MB free hard-disk space
• CD-ROM or DVD drive for installing software from the CD, or internet access to download free programming software
• USB port to use with an EA-MG-PGM-CBL, USB to RS232 Programming Cable Assembly for project transfer from the
programming software to the panel
NOTE: Software and Firmware Version 2.0 or later is required with models EA1-S6ML and
EA1-S6MLW. Available for free download at www.automationdirect.com.
8
B
AK
1
. Information >
2. Setting >
3. Test Menu >
4
. Exit >
U
P
DWN
ENT
ENT
SETUP MENU
B
AK
Total:
1835008 Bytes
U
sage:
26206 Bytes
F
ree:
1808802 Bytes
MEMORY
Examples
Choose C-more 6” Micro-Graphic Panel to PLC Protocols
& Cables
9
NOTE: For the latest list of available
PLC drivers and PLC cables go to
www.automationdirect.com.
Cable Description Cable Part No.
Cables used with serial Port2
AutomationDirect Productivity Series Do-more,
C
LICK,
DDiirreecctt
L
OGIC PLC RJ-12 port, DL05, DL06,
D
L105, DL205, D3-350, D4-450 & H2-WinPLC
(RS-232C)
EA-2CBL
D
D
i
i
r
r
e
e
c
c
t
t
LOGIC (VGA Style) 15-pin port,
DL06, D2-250 (250-1), D2-260
(
RS-232C).
EA-2CBL-1
DDiirreecctt
L
OGIC PLC RJ-11 port, D3-340
(RS-232C).
EA-3CBL
DDiirreecctt
LOGIC DL405 PLC 15-pin D-sub
port, DL405 (RS-232C).
EA-4CBL-1
DDiirreecctt
LOGIC PLC 25-pin D-sub port,
D
L405, D3-350, DL305 DCU and all DCM’s
(RS-232C).
EA-4CBL-2
Allen-Bradley MicroLogix 1000, 1100,
1200 & 1500 (RS-232C)
EA-MLOGIX-CBL
Allen-Bradley SLC 5-03/04/05,
C
ontrolLogix, CompactLogix, FlexLogix
DF1 port (RS-232C)
EA-SLC-232-CBL
Allen-Bradley PLC-5 DF1 port
(RS-232C)
EA-PLC5-232-CBL
Allen-Bradley MicroLogix, SLC 5-01/02/03,
P
LC5 DH485 port (RS-232C)
EA-DH485-CBL
G
E 90/30, 90/70, Micro 90, Versamax Micro
(Port2) 15-pin D-sub port
(RS-422A)
EA-90-30-CBL
MITSUBISHI FX Series 25-pin port
(
RS-422A)
EA-MITSU-CBL
M
ITSUBISHI FX Series 8-pin mini-DIN
(RS-422A)
EA-MITSU-CBL-1
OMRON Host Link (C200 Adapter, C500)
(RS-232C)
EA-OMRON-CBL
Cable Description Cable Part No.
Cables used with serial Port1
AutomationDirect Productivity Series, Do-more,
C
LICK,
DDiirreecctt
L
OGIC PLC RJ-12 port, DL05, DL06,
D
L105, DL205, D3-350, D4-450 & H2-WinPLC
(RS-232C)
DV-1000CBL
Note: The PLC can provide 5 VDC through this cable. No external 12-24
VDC souce is required, however, screen brightness is diminished and
t
he alarm beep will not function.
D
D
i
i
r
r
e
e
c
c
t
t
LOGIC DL405 PLC 15-pin D-sub
port, DL405
(
RS-232C)
D4-1000CBL
DDiirreecctt
LOGIC (VGA Style) 15-pin port,
D
L06, D2-250 (250-1), D2-260
(RS-232C)
Use with DV-1000CBL cable.
FA-15HD
DDiirreecctt
LOGIC PLC 15-pin D-sub port,
DL405
(RS-232C).
FA-CABKIT
DDiirreecctt
L
OGIC PLC RJ-11 port, D3-340
(RS-232C).
OP-3CBL-1
10
Connect the serial communications cable between the C-more Micro-Graphic panel and the PLC. The
panel can be connected to the PLC via the panel’s built-in RJ12 serial communications port (RS-232) or
15-pin serial communications port with either RS-232, RS-422 or RS-485 communications.
Port 1
Port 1
DV-1000CBL
serial cable
CLICK PLC
C-more 6 Inch
Micro-Graphic
Panel
*NOTE: When the panel is powered through Port1 from a connected PLC or PC, the screen brightness
is diminished because the panel is running in Low-Power Mode. For full brightness, connect an
external 12-24 VDC power source to the panel’s power connection. Low-Power Mode should be
used during initial programming only. Connect an external 12-24 VDC power source when the
panel is installed in its application.
Tightening Torque
Power supply wire connection 1.7 lb-in (0.2 Nm)
Required Wire Specif ication
Supported temperature Over 60 °C
Wire Material Copper
Wire Size 16 - 22 AWG
P
LC Drivers
S
erial - port1 or port2
S
erial - port2 only
AutomationDirect Productivity3000 Allen-Bradley DF1 Full Duplex
A
utomationDirect CLICK
A
llen-Bradley DF1 Half Duplex
AuomationDirect Do-more Allen-Bradley PLC5 DF1
AutomationDirect K-sequence Allen-Bradley DH485
AutomationDirect DirectNET GE SNPX (90/30, 90/70, Micro 90, VersaMax Micro)
AutomationDirect Modbus Mitsubishi FX
Modicon Modbus RTU Mitsubishi Q and QnA
Entivity Modbus RTU Omron Host Link (C200 Adapter, C500)
O
mron FINS Serial (CJ1, CS1)
Siemens PPI (S7-200 CPU)
AutomationDirect SOLO Temperature Controller
AutomationDirect GS Drives
Product Package Label
NOTE:
CC--mmoorree
6” Micro-Graphic panels with hardware version R05 and higher must use firmware
version 3.20 or higher
Product Label
R
R
L
ISTEDLISTED
7M177M17
Date code:****Date code:****
5
5443322
1
1
R
05.R05.
MADE IN CHINAMADE IN CHINA
EA1-S6MLW + serial numberEA1-S6MLW + serial number
MODEL:EA1-S6MLMODEL:EA1-S6ML
I
NPUT:12-24V 6.5WINPUT:12-24V 6.5W
IND.CONT.EQ.IND.CONT.EQ.
Hardware Version
UL/CUL/CSA/CE Certification Numbers
Name UL/CUL UL508 CSA CE ISO-9000
CC--mmoorree
Micro-Graphic Panels
& Accessories
E157382 E157382 234884 EN61131-2 Yes
Zobrazit stránku 0
1 2

Shrnutí obsahu

Strany 1 - Additional Help and Support

®3505 HUTCHINSON ROADCUMMING, GA 30040-5860Minimum items required to create a working system:• C-more 6” Micro-Graphic panel• C-more Micro-Graphic Pro

Strany 2 - Specifications

TxDRxDPWRLED Status IndicatorsReplacement PartsUSB to RS232 Programming Cable AssemblyTOP VIEWFRONT VIEWLEFT VIEW0.484[12.3]2.598[66.0]2.539[64.5]1.41

Komentáře k této Příručce

Žádné komentáře